The "RFTC3" series filter is specifically designed to separate the product from the conveying air stream in a vacuum sequencing system and features reverse jet pulse cleaning of the top loading filter media.
Design standards
Carbon steel clean air plenum with four (4) hold down clamps for quick removal of top cover to access filter media
Compressed air header and piping
Aluminum diaphragm valve and factory mounted NEMA 4 solenoid valve (operated from buyer's remote timer or PLC controls)
100% Spun bonded polyester media with 45 pleats per cartridge element
Magnahelic differential pressure gauge (This item shipped loose for field installation)
60 Degree hopper with 6" product discharge flapper and NEMA 4 proximity sensor to sense flapper position
Optional features
Carbon steel, stainless steel or aluminum product contact surfaces
Air operated, flapper type, discharge valve versus standard gravity valve
Pellet service model which eliminates the reverse jet pulse cleaning feature
Orifice gate/Butterfly valve discharge valve versus standard gravity valve
Spool section to increase surge/holding capacity - up to approximately 3 cubic feet
Side mounted regenerative blower
Timer assembly for reverse jet pulse cleaning
Control panel with adjustable timer for vacuum sequencing